Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 448
1.
Protein Sci ; 33(6): e5008, 2024 Jun.
Article En | MEDLINE | ID: mdl-38723181

One of the most important attributes of anti-amyloid antibodies is their selective binding to oligomeric and amyloid aggregates. However, current methods of examining the binding specificities of anti-amyloid ß (Aß) antibodies have limited ability to differentiate between complexes that form between antibodies and monomeric or oligomeric Aß species during the dynamic Aß aggregation process. Here, we present a high-resolution native ion-mobility mass spectrometry (nIM-MS) method to investigate complexes formed between a variety of Aß oligomers and three Aß-specific IgGs, namely two antibodies with relatively high conformational specificity (aducanumab and A34) and one antibody with low conformational specificity (crenezumab). We found that crenezumab primarily binds Aß monomers, while aducanumab preferentially binds Aß monomers and dimers and A34 preferentially binds Aß dimers, trimers, and tetrameters. Through collision induced unfolding (CIU) analysis, our data indicate that antibody stability is increased upon Aß binding and, surprisingly, this stabilization involves the Fc region. Together, we conclude that nIM-MS and CIU enable the identification of Aß antibody binding stoichiometries and provide important details regarding antibody binding mechanisms.


Amyloid beta-Peptides , Antibodies, Monoclonal, Humanized , Ion Mobility Spectrometry , Amyloid beta-Peptides/chemistry , Amyloid beta-Peptides/immunology , Amyloid beta-Peptides/metabolism , Antibodies, Monoclonal, Humanized/chemistry , Antibodies, Monoclonal, Humanized/immunology , Antibodies, Monoclonal, Humanized/metabolism , Ion Mobility Spectrometry/methods , Humans , Mass Spectrometry/methods , Protein Binding , Antibodies, Monoclonal/chemistry , Antibodies, Monoclonal/immunology , Protein Multimerization
2.
J Mass Spectrom ; 59(5): e5026, 2024 May.
Article En | MEDLINE | ID: mdl-38656572

Identification and specific quantification of isomers in a complex biological matrix by mass spectrometry alone is not an easy task due to their identical chemical formula and therefore their same mass-to-charge ratio (m/z). Here, the potential of direct introduction combined with ion mobility-mass spectrometry (DI-IM-MS) for rapid quantification of isomers as human milk oligosaccharides (HMOs) was investigated. Differences in HMO profiles between various analyzed breast milk samples were highlighted using the single ion mobility monitoring (SIM2) acquisition for high ion mobility resolution detection. Furthermore, the Se+ (secretor) or Se- (non-secretor) phenotype could be assigned to breast milk samples studied based on their HMO contents, especially on the response of 2'-fucosyllactose (2'-FL) and lacto-N-fucopentaose I (LNFP I). The possibility of quantifying a specific isomer in breast milk by DI-IM-MS was also investigated. The standard addition method allowed the determination of the 2'-FL despite the presence of other oligosaccharides, including 3-fucosyllactose (3-FL) isomer in breast milk. This proof-of-concept study demonstrated the high potential of such an approach for the rapid and convenient quantification of isomers in complex mixtures.


Ion Mobility Spectrometry , Milk, Human , Oligosaccharides , Trisaccharides , Milk, Human/chemistry , Humans , Trisaccharides/analysis , Trisaccharides/chemistry , Oligosaccharides/analysis , Oligosaccharides/chemistry , Isomerism , Female , Ion Mobility Spectrometry/methods , Mass Spectrometry/methods
3.
Sci Total Environ ; 929: 172483, 2024 Jun 15.
Article En | MEDLINE | ID: mdl-38631629

Per- and polyfluoroalkyl substances (PFAS) remain controversial due to their high persistency and potential human toxicity. Although occupational exposure to PFAS has been widely investigated, the implications of PFAS occurrence in the general population remain to be unraveled. Considering that serum from most people contains PFAS, the aim of this study was to characterize the lipidomic profile in human serum from a general cohort (n = 40) with residual PFAS levels. The geometric means of ∑PFAS (11.8 and 4.4 ng/mL) showed significant differences (p < 0.05) for the samples with the highest (n = 20) and lowest (n = 20) concentrations from the general population respectively. Reverse-phase liquid chromatography coupled to drift tube ion mobility and high-resolution mass spectrometry using dual polarity ionization was used to characterize the lipid profile in both groups. The structural elucidation involved the integration of various parameters, such as retention time, mass-to-charge ratio, tandem mass spectra and collision cross section values. This approach yielded a total of 20 potential biomarkers linked to the perturbed glycerophospholipid metabolism, energy metabolism and sphingolipid metabolism. Among these alterations, most lipids were down-regulated and some specific lipids (PC 36:5, PC 37:4 and PI O-34:2) exhibited a relatively strong Spearman correlation and predictive capacity for PFAS contamination. This study could support further toxicological assessments and mechanistic investigations into the effects of PFAS exposure on the lipidome.


Environmental Pollutants , Fluorocarbons , Lipidomics , Humans , Fluorocarbons/blood , Environmental Pollutants/blood , Chromatography, Liquid , China , Mass Spectrometry , Cohort Studies , Adult , Male , Environmental Exposure/statistics & numerical data , Female , Middle Aged , Ion Mobility Spectrometry/methods , Lipids/blood , Environmental Monitoring/methods , East Asian People
4.
Anal Chem ; 96(18): 7111-7119, 2024 May 07.
Article En | MEDLINE | ID: mdl-38648270

Unsaturated lipids constitute a significant portion of the lipidome, serving as players of multifaceted functions involving cellular signaling, membrane structure, and bioenergetics. While derivatization-assisted liquid chromatography tandem mass spectrometry (LC-MS/MS) remains the gold standard technique in lipidome, it mainly faces challenges in efficiently labeling the carbon-carbon double bond (C═C) and differentiating isomeric lipids in full dimension. This presents a need for new orthogonal methodologies. Herein, a metal- and additive-free aza-Prilezhaev aziridination (APA)-enabled ion mobility mass spectrometric method is developed for probing multiple levels of unsaturated lipid isomerization with high sensitivity. Both unsaturated polar and nonpolar lipids can be efficiently labeled in the form of N-H aziridine without significant side reactions. The signal intensity can be increased by up to 3 orders of magnitude, achieving the nM detection limit. Abundant site-specific fragmentation ions indicate C═C location and sn-position in MS/MS spectra. Better yet, a stable monoaziridination product is dominant, simplifying the spectrum for lipids with multiple double bonds. Coupled with a U-shaped mobility analyzer, identification of geometric isomers and separation of different lipid classes can be achieved. Additionally, a unique pseudo MS3 mode with UMA-QTOF MS boosts the sensitivity for generating diagnostic fragments. Overall, the current method provides a comprehensive solution for deep-profiling lipidomics, which is valuable for lipid marker discovery in disease monitoring and diagnosis.


Aziridines , Lipids , Aziridines/chemistry , Lipids/chemistry , Lipids/analysis , Isomerism , Tandem Mass Spectrometry/methods , Ion Mobility Spectrometry/methods
5.
J Chromatogr A ; 1722: 464903, 2024 May 10.
Article En | MEDLINE | ID: mdl-38615559

High-Field Asymmetric Ion Mobility Spectrometry (FAIMS) is a technique for ion separation and detection based on ion mobility variation under high electronic field. While compensation voltage scanning speed is a fundamental parameter in FAIMS, its impact on spectra remains unclear. In this work, a function referred to as F-EMG is introduced to describe the impact of compensation voltage scanning speed on FAIMS spectra, and the properties of the function are studied. Theoretical analysis emphasizes the impact of the scanning speed on peak height, position, and symmetry, as well as the capability of the F-EMG function to progressively approach Gaussian function at lower scanning speeds. Furthermore, the function indicates that spectra obtained in positive and negative scanning modes exhibits symmetry. An experimental validation, conducted with a custom FAIMS setup and analyzing hydrogen sulfide, ethylbenzene, toluene, styrene, benzene and ammonia, confirms the model's influence on peak features, fitting accuracy, and exhibits a closer alignment with the Gaussian function at lower scanning speeds. Additionally, the experimental data indicate that the spectra show symmetry in positive and negative scanning models. This work not only improves understanding of FAIMS spectral analysis but also introduces a robust method for enhancing data accuracy across varying scanning speeds.


Ion Mobility Spectrometry , Ion Mobility Spectrometry/methods , Models, Theoretical , Ions/chemistry , Ions/analysis
6.
J Am Soc Mass Spectrom ; 35(5): 1012-1020, 2024 May 01.
Article En | MEDLINE | ID: mdl-38634722

To understand the mode of action of bioactive oligosaccharides, such as prebiotics, in-depth knowledge about all structural features, including monosaccharide composition, linkage type, and anomeric configuration, is necessary. Current analytical techniques provide limited information about structural features within complex mixtures unless preceded by extensive purification. In this study, we propose an approach employing cyclic ion mobility spectrometry (cIMS) for the in-depth characterization of oligosaccharides, here demonstrated for disaccharides. We were able to separate galactose and glucose anomers by exploiting the high ion mobility resolution of cIMS. Using the obtained monosaccharide mobilograms as references, we determined the composition and anomeric configuration of 4ß-galactobiose by studying the monosaccharide fragments generated by collision-induced dissociation (CID) before the ion mobility separation. Drift times and individual MS2 spectra of partially resolved reducing-end anomers of 4ß-galactobiose, 4ß-galactosylglucose (lactose), and 4ß-glucosylglucose (cellobiose) were obtained by deconvolution using CID fragmentation induced in the transfer region between the cIMS cell and TOF analyzer. The composition and anomeric configuration of the reducing end anomers of these disaccharides were identified using cIMS2 approaches, where first each anomer was isolated using cIMS and individually fragmented, and the monosaccharide fragments were again separated by cIMS for comparison with monosaccharide standards. With these results we demonstrate the promising application of cIMS for the structural characterization of isomeric oligosaccharides.


Disaccharides , Ion Mobility Spectrometry , Monosaccharides , Ion Mobility Spectrometry/methods , Disaccharides/chemistry , Monosaccharides/chemistry , Carbohydrate Conformation
7.
Molecules ; 29(8)2024 Apr 19.
Article En | MEDLINE | ID: mdl-38675693

Further assessment of ultraviolet C light-emitting diode (UVC-LED) irradiation for influencing shiitake mushrooms' (Lentinus edodes) volatile and sensory properties is needed. In this study, a comparison of UVC-LED irradiation treatment on the flavor profiles in various parts of shiitake mushrooms was conducted using gas chromatography-ion mobility spectrometry (GC-IMS) and sensory analysis. Sixty-three volatile compounds were identified in shiitake mushrooms. The fresh shiitake mushrooms were characterized by the highest values of raw mushroom odors. After UVC-LED treatment, the content of C8 alcohols decreased, especially that of 1-octen-3-ol, while the content of aldehydes increased, especially the content of nonanal and decanal. The score of fatty and green odors was enhanced. For fresh samples, the mushroom odors decreased and the mushroom-like odors weakened more sharply when treated in ethanol suspension than when treated with direct irradiation. The fruit odors were enhanced using direct UVC-LED irradiation for fresh mushroom samples and the onion flavor decreased. As for shiitake mushroom powder in ethanol suspension treated with UVC-LED, the sweaty and almond odor scores decreased and the vitamin D2 content in mushroom caps and stems reached 668.79 µg/g (dw) and 399.45 µg/g (dw), respectively. The results obtained from this study demonstrate that UVC-LED treatment produced rich-flavored, quality mushroom products.


Odorants , Shiitake Mushrooms , Ultraviolet Rays , Volatile Organic Compounds , Shiitake Mushrooms/chemistry , Volatile Organic Compounds/analysis , Odorants/analysis , Ion Mobility Spectrometry/methods , Gas Chromatography-Mass Spectrometry/methods
8.
J Mass Spectrom ; 59(5): e5013, 2024 May.
Article En | MEDLINE | ID: mdl-38605450

Ion mobility spectrometry coupled to mass spectrometry (IMS/MS) is a widely used tool for biomolecular separations and structural elucidation. The application of IMS/MS has resulted in exciting developments in structural proteomics and genomics. This perspective gives a brief background of the field, addresses some of the important issues in making structural measurements, and introduces complementary techniques.


Proteins , Proteomics , Proteins/analysis , Mass Spectrometry/methods , Ion Mobility Spectrometry/methods
9.
J Mass Spectrom ; 59(5): e5021, 2024 May.
Article En | MEDLINE | ID: mdl-38605451

Trapped ion mobility spectrometry-time-of-flight mass spectrometry (TIMS-TOFMS) has emerged as a tool to study protein conformational states. In TIMS, gas-phase ions are guided across the IM stages by applying direct current (DC) potentials (D1-6), which, however, might induce changes in protein structures through collisional activation. To define conditions for native protein analysis, we evaluated the influence of these DC potentials using the metalloenzyme bovine carbonic anhydrase (BCA) as primary test compound. The variation of DC potentials did not change BCA-ion charge and heme content but affected (relative) charge-state intensities and adduct retention. Constructed extracted-ion mobilograms and corresponding collisional cross-section (CCS) profiles gave useful insights in (alterations of) protein conformational state. For BCA, the D3 and D6 potential (which are applied between the deflection transfer and funnel 1 [F1] and the accumulation exit and the start of the ramp, respectively) had most profound effects, showing multimodal CCS distributions at higher potentials indicating gradual unfolding. The other DC potentials only marginally altered the CCS profiles of BCA. To allow for more general conclusions, five additional proteins of diverse molecular weight and conformational stability were analyzed, and for the main protein charge states, CCS profiles were constructed. Principal component analysis (PCA) of the obtained data showed that D1 and D3 exhibit the highest degree of correlation with the ratio of folded and unfolded protein (F/U) as extracted from the mobilograms obtained per set D potential. The correlation of D6 with F/U and protein charge were similar, and D2, D4, and D5 showed an inverse correlation with F/U but were correlated with protein charge. Although DC boundary values for induced conformational changes appeared protein dependent, a set of DC values could be determined, which assured native analysis of most proteins.


Ion Mobility Spectrometry , Proteins , Animals , Cattle , Ion Mobility Spectrometry/methods , Mass Spectrometry/methods , Protein Conformation , Proteins/chemistry , Ions
10.
J Am Soc Mass Spectrom ; 35(5): 982-991, 2024 May 01.
Article En | MEDLINE | ID: mdl-38597281

The structural characterization and differentiation of four types of oligoubiquitin conjugates [linear (Met1)-, Lys11-, Lys48-, Lys63-linked di-, tri-, and tetraubiquitin chains] using ion mobility mass spectrometry are reported. A comparison of collision cross sections for the same linkage of di-, tri-, and tetraubiquitin chains shows differences in conformational elongation for higher charge states due to the interplay of linkage-derived structure and Coulombic repulsion. For di- and triubiquitin chains, this elongation results in a single narrow feature representing an elongated conformation type for multiple higher charge state species. In contrast, higher charge state tetraubiquitin species do not form a single conformer type as readily. A comparison of different linkages in tetraubiquitin chains reveals greater similarity in conformation type at lower charge states; with increasing charge state, the four linkage types diverge in the relative proportions of elongated conformer types with Met1- ≥ Lys11- > Lys63- > Lys48-linkage. These differences in conformational trends could be discussed with respect to biological functions of linkage-specific polyubiquitinated proteins.


Ion Mobility Spectrometry , Ubiquitin , Ion Mobility Spectrometry/methods , Ubiquitin/chemistry , Protein Conformation , Mass Spectrometry/methods , Models, Molecular , Lysine/chemistry
11.
Prostate ; 84(8): 756-762, 2024 Jun.
Article En | MEDLINE | ID: mdl-38497426

BACKGROUND: Many diseases leave behind specific metabolites which can be detected from breath and urine as volatile organic compounds (VOC). Our group previously described VOC-based methods for the detection of bladder cancer and urinary tract infections. This study investigated whether prostate cancer can be diagnosed from VOCs in urine headspace. METHODS: For this pilot study, mid-stream urine samples were collected from 56 patients with histologically confirmed prostate cancer. A control group was formed with 53 healthy male volunteers matched for age who had recently undergone a negative screening by prostate-specific antigen (PSA) and digital rectal exam. Headspace measurements were performed with the electronic nose Cyranose 320TM. Statistical comparison was performed using principal component analysis, calculating Mahalanobis distance, and linear discriminant analysis. Further measurements were carried out with ion mobility spectrometry (IMS) to compare detection accuracy and to identify potential individual analytes. Bonferroni correction was applied for multiple testing. RESULTS: The electronic nose yielded a sensitivity of 77% and specificity of 62%. Mahalanobis distance was 0.964, which is indicative of limited group separation. IMS identified a total of 38 individual analytical peaks, two of which showed significant differences between groups (p < 0.05). To discriminate between tumor and controls, a decision tree with nine steps was generated. This model led to a sensitivity of 98% and specificity of 100%. CONCLUSIONS: VOC-based detection of prostate cancer seems feasible in principle. While the first results with an electronic nose show some limitations, the approach can compete with other urine-based marker systems. However, it seems less reliable than PSA testing. IMS is more accurate than the electronic nose with promising sensitivity and specificity, which warrants further research. The individual relevant metabolites identified by IMS should further be characterized using gas chromatography/mass spectrometry to facilitate potential targeted rapid testing.


Electronic Nose , Ion Mobility Spectrometry , Prostatic Neoplasms , Volatile Organic Compounds , Humans , Male , Volatile Organic Compounds/urine , Volatile Organic Compounds/analysis , Prostatic Neoplasms/urine , Prostatic Neoplasms/diagnosis , Ion Mobility Spectrometry/methods , Aged , Middle Aged , Pilot Projects , Sensitivity and Specificity , Aged, 80 and over
12.
J Am Soc Mass Spectrom ; 35(4): 793-803, 2024 Apr 03.
Article En | MEDLINE | ID: mdl-38469802

The opioid crisis in the United States is being fueled by the rapid emergence of new fentanyl analogs and precursors that can elude traditional library-based screening methods, which require data from known reference compounds. Since reference compounds are unavailable for new fentanyl analogs, we examined if fentanyls (fentanyl + fentanyl analogs) could be identified in a reference-free manner using a combination of electrospray ionization (ESI), high-resolution ion mobility (IM) spectrometry, high-resolution mass spectrometry (MS), and higher-energy collision-induced dissociation (MS/MS). We analyzed a mixture containing nine fentanyls and W-15 (a structurally similar molecule) and found that the protonated forms of all fentanyls exhibited two baseline-separated IM distributions that produced different MS/MS patterns. Upon fragmentation, both IM distributions of all fentanyls produced two high intensity fragments, resulting from amine site cleavages. The higher mobility distributions of all fentanyls also produced several low intensity fragments, but surprisingly, these same fragments exhibited much greater intensities in the lower mobility distributions. This observation demonstrates that many fragments of fentanyls predominantly originate from one of two different gas-phase structures (suggestive of protomers). Furthermore, increasing the water concentration in the ESI solution increased the intensity of the lower mobility distribution relative to the higher mobility distribution, which further supports that fentanyls exist as two gas-phase protomers. Our observations on the IM and MS/MS properties of fentanyls can be exploited to positively differentiate fentanyls from other compounds without requiring reference libraries and will hopefully assist first responders and law enforcement in combating new and emerging fentanyls.


Fentanyl , Tandem Mass Spectrometry , Humans , Tandem Mass Spectrometry/methods , Protein Subunits , Ion Mobility Spectrometry/methods
13.
Talanta ; 273: 125910, 2024 Jun 01.
Article En | MEDLINE | ID: mdl-38492284

Paw San rice, also known as "Myanmar pearl rice", is considered the highest quality rice in Myanmar. There are considerable differences in terms of the premium commercial value of Paw San rice, which is an incentive for fraud, e.g. adulteration with cheaper rice varieties or mislabelling its geographical origin. Shwe Bo District is one of the most popular rice growing areas in the Sagaing region of Myanmar which produces the most valued and highly priced Paw San rice (Shwe Bo Paw San). The verification of the geographical origin of Paw San rice is not readily undertaken in the rice supply chain because the existing analytical approaches are time-consuming and expensive. Therefore, there is a need for rapid, robust and cost-effective analytical techniques for monitoring the authenticity and geographical origin of Paw San rice. In this 4-year study, two rapid screening techniques, Fourier-transform near-infrared (FT-NIR) spectroscopy and headspace-gas chromatography-ion mobility spectrometry (HS-GC-IMS), coupled with chemometric modelling, were applied and compared for the regional differentiation of Paw San rice. In addition, low-level fusion of the FT-NIR and HS-GC-IMS data was performed and its effect on the discriminative power of the chemometric models was assessed. Extensive model validation, including the validation using independent samples from a different production year, was performed. Furthermore, the effect of the sample preparation technique (grinding versus no sample preparation) on the performance of the discriminative model, obtained with FT-NIR spectral data, was assessed. The study discusses the suitability of FT-NIR spectroscopy, HS-GC-IMS and the combination of both approaches for rapid determination of the geographical origin of Paw San rice. The results demonstrated the excellent potential of the FT-NIR spectroscopy as well as HS-GC-IMS for the differentiation of Paw San rice cultivated in two distinct geographical regions. The OPLS-DA model, built using FT-NIR data of rice from 3 production years, achieved 96.67% total correct classification rate of an independent dataset from the 4th production year. The DD-SIMCA model, built using FT-NIR data of ground rice, also demonstrated the highest performance: 94% sensitivity and 97% specificity. This study has demonstrated that FT-NIR spectroscopy can be used as an accessible, rapid and cost-effective screening tool to discriminate between Paw San rice cultivated in the Shwe Bo and Ayeyarwady regions of Myanmar.


Oryza , Spectroscopy, Near-Infrared , Spectroscopy, Near-Infrared/methods , Chemometrics , Gas Chromatography-Mass Spectrometry/methods , Ion Mobility Spectrometry/methods , Myanmar
14.
Anal Chem ; 96(9): 3794-3801, 2024 Mar 05.
Article En | MEDLINE | ID: mdl-38386844

Gas chromatography combined with ion mobility spectrometry (GC-IMS) is a powerful separation and detection technique for volatile organic compounds (VOC). This combination is characterized by exceptionally low detection limits in the low ppbv range, high 2-dimensional selectivity, and robust operation. These qualities make it an ideal tool for nontarget screening approaches. Fermentation broths contain a substantial number of VOC, either from the medium or produced by microbial metabolism, that are currently not regularly measured for process monitoring. In this study, Escherichia coli, Saccharomyces cerevisiae, Levilactobacillus brevis, and Pseudomonas fluorescens were exemplarily used as model organisms and cultivated, and the headspace was analyzed by GC-IMS. Additionally, mixed cultures for every combination of two of the microorganisms were also characterized. Multivariate data analysis of the GC-IMS data revealed that it is possible to differentiate between the microorganisms using PLS-DA with a prediction accuracy of 0.92. The mixed cultures could be separated from the pure cultures with accuracies between 0.87 and 1.00 depending on the organism. GC-IMS data correlate with the optical density and can be used to follow and model growth curves. The root mean squared errors ranged between 10 and 20% of the maximum value, depending on the organism. Peak identification with reference compounds did not reveal specific marker compounds, rather the pattern was found to be responsible for the model performance.


Ion Mobility Spectrometry , Volatile Organic Compounds , Ion Mobility Spectrometry/methods , Gas Chromatography-Mass Spectrometry/methods , Volatile Organic Compounds/analysis , Fermentation , Multivariate Analysis , Escherichia coli
15.
J Chem Inf Model ; 64(5): 1533-1542, 2024 Mar 11.
Article En | MEDLINE | ID: mdl-38393779

The rotationally averaged collision cross-section (CCS) determined by ion mobility-mass spectrometry (IM-MS) facilitates the identification of various biomolecules. Although machine learning (ML) models have recently emerged as a highly accurate approach for predicting CCS values, they rely on large data sets from various instruments, calibrants, and setups, which can introduce additional errors. In this study, we identified and validated that ion's polarizability and mass-to-charge ratio (m/z) have the most significant predictive power for traveling-wave IM CCS values in relation to other physicochemical properties of ions. Constructed solely based on these two physicochemical properties, our CCS prediction approach demonstrated high accuracy (mean relative error of <3.0%) even when trained with limited data (15 CCS values). Given its ability to excel with limited data, our approach harbors immense potential for constructing a precisely predicted CCS database tailored to each distinct experimental setup. A Python script for CCS prediction using our approach is freely available at https://github.com/MSBSiriraj/SVR_CCSPrediction under the GNU General Public License (GPL) version 3.


Ion Mobility Spectrometry , Ions/chemistry , Ion Mobility Spectrometry/methods
16.
Food Res Int ; 179: 114023, 2024 Mar.
Article En | MEDLINE | ID: mdl-38342542

Currently, the authentication of ground black pepper is a major concern, creating a need for a rapid, highly sensitive and specific detection tool to prevent the introduction of adulterated batches into the food chain. To this aim, head space gas-chromatography ion mobility spectrometry (HS-GC-IMS), combined with machine learning, is tested in this initial, proof-of-concept study. A broad variety of authentic samples originating from eight countries and three continents were collected and spiked with a range of adulterants, both endogenous sub-products and an assortment of exogenous materials. The method is characterized by no sample preparation and requires 20 min for chromatographic separation and ion mobility data acquisition. After an explorative analysis of the data, those were submitted to two different machine learning algorithms (partial least squared discriminant analysis-PLS-DA and support vector machine-SVM). While the PLS-DA model did not provide fully satisfactory performances, the combination of HS-GC-IMS and SVM successfully classified the samples as authentic, exogenously-adulterated or endogenously-adulterated with an overall accuracy of 90 % and 96 % on withheld test set 1 and withheld test set 2, respectively (at a 95 % confidence level). Some limitations, expected to be mitigated by further research, were encountered in the correct classification of endogenously adulterated ground black pepper. Correct categorization of the ground black pepper samples was not adversely affected by the operator or the time span of data collection (the method development and model challenge were carried out by two operators over 6 months of the study, using ground black pepper harvested between 2015 and 2019). Therefore, HS-GC-IMS, coupled to an intelligent tool, is proposed to: (i) aid in industrial decision-making before utilization of a new batch of ground black pepper in the production chain; (ii) reduce the use of time-consuming conventional analyses and; (iii) increase the number of ground black pepper samples analyzed within an industrial quality control frame.


Piper nigrum , Volatile Organic Compounds , Gas Chromatography-Mass Spectrometry/methods , Ion Mobility Spectrometry/methods , Volatile Organic Compounds/analysis , Discriminant Analysis
17.
Anal Chim Acta ; 1289: 342204, 2024 Feb 08.
Article En | MEDLINE | ID: mdl-38245205

BACKGROUND: Gas chromatography-ion mobility spectrometry (GC-IMS) is a powerful analytical technique which has gained widespread use in a variety of fields. Detecting peaks in GC-IMS data is essential for chemical identification. Topological data analysis (TDA) has the ability to record alterations in topology throughout the entire spectrum of GC-IMS data and retain this data in diagrams known as persistence diagrams. To put it differently, TDA naturally identifies characteristics such as mountains, volcanoes, and their higher-dimensional equivalents within the original data and measures their significance. RESULTS: In the present contribution, a novel approach based on persistent homology (a flagship technique of TDA) is suggested for automatic 2D peak detection in GC-IMS. For this purpose, two different GC-IMS data examples (urine and olive oil) are used to show the performance of the proposed method. The outputs of the algorithm are GC-IMS chromatogram with detected peaks, persistence plot showing the importance (intensity) of the detected peaks and a table with retention times (RT), drift times (DT), and persistence scores of detected peaks. The RT and DT can be used for identification of the peaks and persistence scores for quantitation. Additionally, watershed segmentation is applied to the GC-IMS images to index individual peaks and segment overlapping compounds allowing for a more accurate identification and quantification of individual peaks. SIGNIFICANCE: Inspection of the results for GC-IMS datasets showed the accurate and reliable performance of the proposed strategy based on persistent homology for automatic 2D GC-IMS peak detection for qualitative and quantitative analysis. In addition, this approach can be easily extended to other types of hyphenated chromatographic and/or spectroscopic data.


Body Fluids , Volatile Organic Compounds , Gas Chromatography-Mass Spectrometry/methods , Ion Mobility Spectrometry/methods , Olive Oil/analysis , Body Fluids/chemistry , Algorithms , Volatile Organic Compounds/analysis
18.
Food Res Int ; 176: 113842, 2024 Jan.
Article En | MEDLINE | ID: mdl-38163733

Oil autoxidation is an early process of food deterioration, monitoring oil oxidation is therefore of great significance to ensure food quality and safety. In this study, a detection method of the primary and secondary oxidative products was developed by gas chromatography ion mobility spectrometry (GC-IMS).The secondary oxidative products was analyzed by GC-IMS. Then, the relationships between peroxide values and the contents of secondary oxidative products were investigated by constructing a prediction model of peroxide value of rapeseed oil with the help of secondary oxidative products and chemometrics. The coefficient of determination Q2 of the model validation set is 0.96, and the RMSECV is 0.1570 g/100 g. These validation results indicated that secondary oxidative products could also reflect the content of the primary oxidative products. Moreover, 10 characteristic markers related to oxidative rancidity were identified for monitoring edible oil rancidity and oxidative stability.


Food Quality , Ion Mobility Spectrometry , Gas Chromatography-Mass Spectrometry/methods , Ion Mobility Spectrometry/methods , Rapeseed Oil , Peroxides
19.
J Am Soc Mass Spectrom ; 35(2): 365-377, 2024 Feb 07.
Article En | MEDLINE | ID: mdl-38175933

The accumulation of very large ion populations in traveling wave (TW)-based Structures for Lossless ion Manipulations (SLIM) has been studied to better understand aspects of "in-SLIM" ion accumulation, and particularly its use in conjunction with ion mobility spectrometry (IMS). A linear SLIM ion path was implemented that had a "gate" for blocking and accumulating ions for arbitrary time periods. Removing the gate potential caused ions to exit, and the spatial distributions of accumulated ions examined. The ion populations for a set of peptides increased approximately linearly with increased accumulation times until space change effects became significant, after which the peptide precursor ion populations decreased due to growing space charge-related ion activation, reactions, and losses. Ion activation increased with added storage times and the TW amplitude. Lower amplitude TWs in the accumulation/storage region prevented or minimized ion losses or ion heating effects that can also lead to fragmentation. Our results supported the use of an accumulation region close to the SLIM entrance for speeding accumulation, minimizing ion heating, and avoiding ion population profiles that result in IMS peak tailing. Importantly, space charge-driven separations were observed for large populations of accumulated species and attributed to the opposing effects of space charge and the TW. In these separations, ion species form distributions or peaks, sometimes moving against the TW, and are ordered in the SLIM based on their mobilities. Only the highest mobility ions located closest to the gate in the trapped ion population (and where the highest ion densities were achieved) were significantly activated. The observed separations may offer utility for ion prefractionation of ions and increasing the dynamic range measurements, increasing the resolving power of IMS separations by decreasing peak widths for accumulated ion populations, and other purposes benefiting from separations of extremely large ion populations.


Ion Mobility Spectrometry , Peptides , Ion Mobility Spectrometry/methods , Peptides/analysis , Ions/chemistry
20.
Proteomics ; 24(3-4): e2200471, 2024 Feb.
Article En | MEDLINE | ID: mdl-38282202

Enzymatic catalysis is one of the fundamental processes that drives the dynamic landscape of post-translational modifications (PTMs), expanding the structural and functional diversity of proteins. Here, we assessed enzyme specificity using a top-down ion mobility spectrometry (IMS) and tandem mass spectrometry (MS/MS) workflow. We successfully applied trapped IMS (TIMS) to investigate site-specific N-ε-acetylation of lysine residues of full-length histone H4 catalyzed by histone lysine acetyltransferase KAT8. We demonstrate that KAT8 exhibits a preference for N-ε-acetylation of residue K16, while also adding acetyl groups on residues K5 and K8 as the first degree of acetylation. Achieving TIMS resolving power values of up to 300, we fully separated mono-acetylated regioisomers (H4K5ac, H4K8ac, and H4K16ac). Each of these separated regioisomers produce unique MS/MS fragment ions, enabling estimation of their individual mobility distributions and the exact localization of the N-ε-acetylation sites. This study highlights the potential of top-down TIMS-MS/MS for conducting enzymatic assays at the intact protein level and, more generally, for separation and identification of intact isomeric proteoforms and precise PTM localization.


Ion Mobility Spectrometry , Tandem Mass Spectrometry , Ion Mobility Spectrometry/methods , Histones/metabolism , Protein Processing, Post-Translational , Acetylation
...